Skip to main content
  • Research article
  • Open access
  • Published:

Multiparametric functional magnetic resonance imaging for evaluation of hepatic warm ischemia-reperfusion injury in a rabbit model

Abstract

Background

To assess the feasibility of noninvasive and quantitative evaluation of hepatic pathophysiological changes in rabbit hepatic warm ischemia-reperfusion injury (WIRI) models by using intravoxel incoherent motion (IVIM), diffusion tensor imaging (DTI) and blood oxygen level dependent (BOLD) MRI.

Methods

Twenty rabbits were randomly divided into hepatic WIRI model group and sham-operation group (n = 10 for each group). Hepatic WIRI was induced in rabbit by occluding hepatic inflow for 30 min and reperfusion for 6 h. The control group only underwent laparotomy and liver ligament dissection. IVIM with 11 b values (0 to 800 s/mm2), DTI with 2 b values (0 and 500 s/mm2) on 12 diffusion directions, and BOLD MRI with 9 TE (2.57 to 24.25 ms) were performed at 3 T clinical MR scanner. Rabbits were sacrificed for biochemical and histopathological analysis after MR scanning. All of functional MR, biochemical and histopathological parameters were analyzed by independent sample t test, Mann-Whitney U test, Pearson and Spearman correlation methods.

Results

All of MR parameters showed moderate to excellent interobserver reproducibility. True diffusion (Dslow), pseudodiffusion (Dfast), perfusion fraction (PF), and mean diffusitivity (MD) were lower in WIRI models than in control rabbits (P < 0.01), R2* was higher in WIRI models than in control rabbits (P < 0.001), while fractional anisotropy (FA) showed no statistical difference. There were significant differences in I score and all of biochemical parameters between the two groups (P < 0.01). Functional MR parameters corresponded well with all of biochemical parameters and some of histopathological parameters (P < 0.05). Histopathological analysis showed the structure and morphology of hepatic lobule was normal and clear in control rabbits, while diffuse hepatocyte swelling, central vein and sinusoids congestion, and inflammatory cell infiltration in WIRI models.

Conclusions

IVIM, DTI, and BOLD MRI are noninvasive and useful techniques for assessing the microenvironment changes of hepatic WIRI in rabbit models.

Peer Review reports

Background

Hepatic ischemia–reperfusion injury (IRI) is the most common cause of liver damage during liver transplantation [1]. Donation after cardiac death (DCD) has expanded the donor pool for liver transplantation, especially in Asian countries [2,3,4]. However, compared with donation after brain death and living donation, DCD liver grafts are associated with significantly worse outcome [5,6,7,8,9]. The hepatic IRI of DCD liver grafts is attributed to blood supply returns to the tissue after a period of ischemia during graft harvest (also called warm ischemia), graft storage (cold ischemia) and graft implantation (reperfusion). The extent of injury during cold ischemia and reperfusion depends on the duration during the warm ischemia. Reperfusion of ischemic tissue is essential for survival, it also initiates oxidative damage, cell death and aberrant immune responses through the generation of mitochondrial reactive oxygen species (ROS) [10]. Therefore, Hepatic warm ischemia–reperfusion injury (WIRI) causes sever ischemia and anoxia, oxidation/antioxidation imbalance, and excessive inflammatory response [11], which result in liver microcirculatory disorders and histological damage.

Although liver biopsy is considered the standard technique for diagnosis of liver damage, it is impossible to be a routine and dynamic monitoring method, because it is an invasive method with possible complications and sampling error [12, 13]. Instead, MR imaging has played an important role in this setting [14,15,16,17,18]. Intravoxel incoherent motion (IVIM) MRI and diffusion tensor imaging (DTI) are advanced techniques based on diffusion-weighted imaging (DWI). IVIM allows for separation perfusion (or microcirculation) related diffusion from pure molecular diffusion, by analyzing the signal decay of multi-b-value DWI [19, 20]. DTI can reveal microstructural characteristics of biological tissue, which can detect the degree of diffusion in multiple dimensions by using at least six or more gradient directions [21, 22]. Blood oxygen level–dependent (BOLD) MRI is a MRI technique that using deoxyhemoglobin as an endogenous contrast to reflect alterations in blood oxygenation, blood flow, and blood volume [23]. To our knowledge, a limited number of studies have investigated the feasibility of IVIM, DTI and BOLD MRI to characterize liver fibrosis [23, 24], liver cirrhosis [25], and hepatic tumors [26,27,28], while only a few reports assessed the role of a single technique above mentioned in the hepatic WIRI [18, 29].

Therefore, we attempt to determine the feasibility of noninvasive evaluation and characterization of hepatic diffusion, perfusion and oxygenation changes of hepatic WIRI in a rabbit model by comprehensively using IVIM, DTI and BOLD MRI.

Methods

Animal model

This study was approved by the local Animal Experimentation Ethics Committee and performed in accordance with institutional guidelines (No: 2017N030KY). Twenty adult New Zealand White rabbits weighing 2.5-3.0 kg were randomly divided into two groups: hepatic WIRI model group (n = 10) and sham-operation control group (n = 10). All of rabbits were anesthetized with intravenous injection of 5% amobarbital (Sigma-Aldrich Chemical, St. Louis, MO, USA) at a dose of 1 mL/kg. Hepatic WIRI was induced by temporarily clamping the hepatic artery and portal vein for 30 min and reperfusion for 6 h, followed by MRI studies. The control group only underwent laparotomy and liver ligament dissection. All experimental procedures were performed by a well-experienced surgeon (with 15 years of experience in general surgery).

MR imaging

MR data acquisition was performed under 6-channel phased array body coil of 3 T clinical system (MAGNETOM Trio Tim, Siemens Healthcare, Erlangen, Germany). All rabbits were anesthetized with intramuscular injection xylazine hydrochloride (Huamu Animal, Jilin, China) at a dose of 0.2 mL/kg, and then positioned supinely with a belt to reduce the respiratory motion.

Axial IVIM images were acquired using a free-breathing single-shot echo-planar imaging (ss-EPI) prototype sequence with the following parameters: TR/TE of 1000/57.2 ms, EPI factor of 96, voxel size of 1.9 × 1.9 × 4.0 mm3, field of view (FOV) of 180 × 180 mm2, slice thickness of 4 mm, matrix of 96 × 96, with 3 measurements averaged and an acquisition time of 2 min. DW gradients (i.e. 11 b values of 0, 20, 40, 60, 80, 100, 150, 200, 400, 600, and 800 s/mm2) were applied in three orthogonal directions and were subsequently averaged.

Axial DTI images were acquired using a free-breathing ss-EPI prototype sequence with the following parameters: TR/TE of 3800/86 ms, EPI factor of 88, voxel size of 1.4 × 1.4 × 4.0 mm3, FOV of 180 × 180 mm2, slice thickness of 4 mm, matrix of 128 × 128, with two b values of 0 and 500 s/mm2 on 12 diffusion directions, and an acquisition time of 309 s.

All of animals were exposed to room air (78% N2, 20% O2) to maintain normoxia state. Liver BOLD imaging was performed using a multi-echo gradient echo pulse sequence with free-breathing examination to acquire axial T2*-weighted images. Other imaging parameters included: TR of 75 ms, TE of 2.57-24.25 ms (9 echoes), flip angle of 30°, voxel size of 2.0 × 1.6 × 4.0 mm3, FOV of 300 × 225 mm2, matrix of 192 × 154, slice thickness of 4 mm, number of slices 18, and a total examination time of 76 s.

Image analysis

Image analysis was performed with prototype software supplied by the manufacturer (Siemens Healthcare, Erlangen, Germany). Three IVIM-derived parameters (Dslow: the true diffusion as reflected by pure molecular diffusion, Dfast: the pseudodiffusion coefficient related to perfusion, and PF: the perfusion fraction which represents a fractional volume of microcirculation within a voxel) were calculated by a full bi-exponential fitting of the MR signal intensity images of all b values on a pixel-by-pixel basis, using the equation as previously described [30].

For quantitative analysis of DTI, the mean diffusitivity (MD) and fractional anisotropy (FA) maps were generated automatically as previously described from all diffusion-weighted images on the postprocessing workstation. The range of FA value is from 0 to 1 [26].

BOLD-derived T2* (ms) and R2* (1/T2*, sec−1) were calculated by fitting a monoexponential, voxel by voxel, to the signal intensity-echo time curve [23, 31]. Color-coded parametric images of R2* were obtained using commercial software (Image J, NIH, Bethesda, MD, USA).

All regions of interest (ROIs) were manually positioned by two radiologists (with 10 and 5 years of experience in abdominal MR imaging) on images with b value of 0 s/mm2, and then were copied to the corresponding Dslow, Dfast, PF, MD, FA, and T2* maps. Six circular ROIs were manually drawn on 3 central slices of the liver to avoid the inclusion of large intrahepatic vessels/bile ducts and the margin. The mean size of all ROIs in the liver is 12 pixels ±2. The mean value of the six ROIs was used for the final analysis.

Biochemical and Histopathological analysis

After MR scanning, 4 ml blood was collected from the auricular vein of each animal. The blood was centrifuged to obtain serum. Serum liver function parameters, including alanine transaminase (ALT), aspartate transaminase (AST), and lactate dehydrogenase (LDH) were measured using automatic biochemistry analyzer (HITACHI TAB-40F2, Japan) with standard procedures. The rabbits were then sacrificed by an overdose of 5% amobarbital by intravenous injection, and 1 g liver tissue were collected for each animal. The oxidant/antioxidant, and inflammatory parameters, including malondialdehyde (MDA), superoxide dismutase (SOD), and myeloperoxidase (MPO) of liver tissue were measured using spectrophotometry method (Jiancheng Bio, Nanjing, China).

Liver specimens were fixed in 4% phosphate-buffered formaldehyde and embedded in paraffin. After that, hematoxylin and eosin (H&E) staining was performed on each section for histological analysis. All HE-stained tissue sections were examined microscopically under an optical microscope (Olympus BX50, Japan). The stages of hepatic inflammation/necrosis (I score) and liver fibrosis (F score) were scored by one histopathologist (with 16 years of liver pathology) using the METAVIR classification system [32] and blinded to the results of the group and MR.

Statistical analysis

Interobserver reproducibility was assessed by measuring intraclass correlation coefficients (ICC) [33]. Statistical analysis was performed using independent sample t test, and Mann-Whitney U test for two group comparisons of the functional MR parameters and biochemical parameters. The Pearson and Spearman correlation coefficient was calculated to assess the correlations between functional MR parameters and biochemical parameters. The data were analyzed using SPSS 17.0 software (SPSS, Chicago, IL, USA), P < 0.05 was considered statistically significant.

Results

Interobserver agreement of functional MR parameters

For IVIM, Dslow and PF values had excellent interobserver agreement with ICC of 0.960 (0.839-0.990), and 0.926 (0.701-0.982), respectively, and Dfast values showed moderate agreement with ICC of 0.663 (0.355-0.916). For DTI, MD and FA values showed excellent interobserver agreement with ICC of 0.890 (0.722-0.956), and 0.823 (0.554-0.930), respectively. For BOLD, R2* values showed excellent interobserver agreement with ICC of 0.870 (0.671-0.948).

Comparison of functional MR parameters between two groups

Dslow, Dfast, PF, and MD of model group were significantly lower than control group (P < 0.01), while R2* of model group was significantly higher than control group (P < 0.001). FA changes between two groups was not statistically significant (P > 0.05) (Table 1). The corresponding typical examples of functional MR parametric maps were shown in Fig. 1. Compared with control group, Dfast and PF in model group decreased 25.01 ± 16.69%, and 34.45 ± 9.63%, respectively, while R2* increased 36.38 ± 18.31%.

Table 1 Functional MR measurements between two groups
Fig. 1
figure 1

Typical IVIM, DTI and BOLD MRI parametric maps of a control rabbit (upper row) and a hepatic WIRI model rabbit (lower row). Dslow, Dfast, PF, and MD maps show lower signals, while R2* show higher signals in the rabbit with hepatic WIRI (lower row) than in the rabbit with normal liver (upper row)

Laboratory findings and correlation analysis

There were significant differences in ALT, AST, LDH, MDA, MPO, and SOD between the two groups (P < 0.01) (Table 2). ALT, AST, LDH, MDA, and MPO of model group were significantly higher than control group (P < 0.01), while SOD of model group was significantly lower than control group (P < 0.001). The correlation analysis showed that there were significant negative correlations between Dslow, Dfast, PF, MD and liver function, oxidant, inflammatory parameters (ALT, AST, LDH, MDA, MPO) (all P < 0.05), and positive correlations between Dslow, Dfast, PF, MD and antioxidant parameter (SOD) (all P < 0.05). Converse results were seen in the correlations between R2* and biochemical parameters (all P < 0.05). There were no significant correlations between FA and biochemical paratemers (all P > 0.05). These results are summarized in Table 3.

Table 2 Summary of biochemical and histopathological parameters between two groups
Table 3 Summary of correlations between functional MR parameters and biochemical, histopathological parameters

Histopathological analysis

HE staining revealed that in the control group, the structure and morphology of hepatic lobule was normal and clear, there were no hepatocyte edema, sinusoids dilatation and inflammatory cell infiltration. Conversely, all hepatic WIRI rabbits had evidence of hepatocyte edema, inflammatory infiltration, central vein and sinusoids congestion, and mild proliferation of fibrous tissue (Fig. 2).

Fig. 2
figure 2

Hematoxylin-eosin (HE) staining images of liver. a. a control rabbit (magnification, ×100), the structure and morphology of hepatic lobule was normal and clear, there were no hepatocyte edema, sinusoids congestion and inflammatory cell infiltration. b and c. different regions of a hepatic WIRI rabbit model (magnification, ×100). b with regions of hepatocyte swelling indicated by black arrows, central vein and sinusoids congestion indicated by white arrows, and mild proliferation of fibrous tissue indicated by green arrow. c with regions of inflammatory cell infiltration indicated by black arrows

There were significant differences in I score (P < 0.01), while no significant differences in F score between two groups (P > 0.05) (Table 2). The correlation analysis showed that there were significant correlations between I score, F score and some of the functional MR parameters (P < 0.05) (Table 3).

Discussion

In our preliminary sudy, we have proved the feasibility and reproducibility of IVIM, DTI and BOLD MRI as noninvasive alternatives to characterize the microenvironment changes of hepatic WIRI.

There have been no convincing data on the changes in liver IVIM and DTI study prior to this report [18, 29]. Our study demonstrated that there were significant differences in IVIM-derived Dslow, Dfast, PF values, DTI-derived MD values, and BOLD-derived R2* values between the two groups, which indicated that IVIM, DTI and BOLD MRI were sensitive to hepatic WIRI. Meanwhile, all of these parameters corresponded well with liver function (ALT, AST, and LDH), oxidant/antioxidant (MDA and SOD), and inflammatory parameters (MPO), which indicated that IVIM, DTI and BOLD MRI can effectively characterize the hepatic cellular injury and microscopic alteration of hepatic WIRI.

Histopathologically, in the hepatic WIRI model, hepatocyte swelling and inflammatory cell infiltration restrict the water molecular diffusion, leading to the decrease of hepatic diffusion (Dslow and MD values). In the present study, we first found that there were significant differences in I score between model group and control group, which confirmed the hepatocyte death, swelling and inflammatory cell infiltration in hepatic WIRI tissue. On the other hand, occlusion of hepatic artery and portal vein resulted in hepatic ischemia and anoxia, central vein and sinusoids congestion, and presence of “no-reflow” phenomenon after reperfusion [34], which causes reduced hepatic perfusion and oxygenation, that is, decrease of Dfast, PF values, and the increase of R2* value.

There is only one study in the literature on the use of DTI for hepatic IRI, in which a 7 T scanner was used [18]. They reported that FA 2 h after 30-min total hepatic IRI was significantly higher than that before and 1 day after IRI. In contrast to this study, although the FA showed a trend toward higher values in hepatic WIRI group, there was no statistical difference in FA between two groups in our study. So further studies are required to clarify where or not species difference is also one of the factors responsible for this variation in FA value in addition to differences in imaging protocol.

BOLD MRI can monitor the oxygenation state and blood perfusion of tissue [35]. The interpretation of BOLD MRI may be difficult in some situations, because both decreased blood flow and low oxygenation level can result in increased R2* value. For the first time, we attempt to evaluate the feasibility of characterization of hepatic WIRI in a rabbit model by using BOLD MRI. To avoid the documented effects of increasing glucose levels on blood flow [36] and R2* [37] in the liver, all rabbits were imaged in fasting conditions in our study. We found that when compared with control group, Dfast decreased 25.01 ± 16.69% in model group, while R2* increased 36.38 ± 18.31%. Therefore, combined application of BOLD MRI and IVIM technique, which can evaluate tissue perfusion without using of contrast agent, provide a better understanding both tissue oxygenation states and tissue perfusion, and in-depth assessment of hepatic WIRI pathophysiological changes.

Our study has certain limitations. First, we studied a small number of rabbits. However, this was an exploratory pilot study and herein we reported our preliminary findings. Second, hepatic WIRI is a dynamic process which is intrinsically time-dependent, while the model in this study was characterized only at a specific time frame. A longitudinal follow-up study may reveal the changes of disease evolution, which should be investigated in further studies. Third, we assessed only steady-state normoxia BOLD imaging rather than using extrinsic challenges, such as inhaled carbogen gas or 100% oxygen [23, 28, 38]. However, the use of extrinsic gas stimulation is technically difficult and time consuming. Our results demonstrated a statistically significant difference, which mean room air was sufficient to draw conclusions.

Conclusions

IVIM, DTI, and BOLD MR imaging are useful and noninvasive techniques for evaluating in vivo hepatic microenvironment changes in a rabbit hepatic WIRI model.

Abbreviations

ADC:

Apparent diffusion coefficient

ALT:

Slanine transaminase

AST:

Aspartate transaminase

BOLD:

Blood oxygen level–dependent

DCD:

Donation after cardiac death

Dfast:

Pseudodiffusion or perfusion related diffusion

Dslow:

True diffusion or pure molecular diffusion

DTI:

Diffusion tensor imaging

DWI:

Diffusion weighted imaging

FA:

Fractional anisotropy

HE:

Hematoxylin and eosin

ICC:

Intraclass correlation coefficients

IVIM:

Intravoxel incoherent motion

LDH:

Lactate dehydrogenase

MD:

Mean diffusitivity

MDA:

Malondialdehyde

MPO:

Myeloperoxidase

PF:

Perfusion fraction

ROI:

Regions of interest

SOD:

Superoxide dismutase

TNF-α:

Tumor necrosis factor-α

WIRI:

Hepatic warm ischemia-reperfusion injury

References

  1. Gracia-Sancho J, Casillas-Ramírez A, Peralta C. Molecular pathways in protecting the liver from ischaemia/reperfusion injury: a 2015 update. Clin Sci [Lond]. 2015;129:345–62.

    Article  CAS  Google Scholar 

  2. Pan X, Apinyachon W, Xia W, et al. Perioperative complications in liver transplantation using donation after cardiac death grafts: a propensity-matched study. Liver Transpl. 2014;20:823–30.

    Article  PubMed  Google Scholar 

  3. Klein AS, Messersmith EE, Ratner LE, Kochik R, Baliga PK, Ojo AO. Organ donation and utilization in the United States, 1999-2008. Am J Transplant. 2010;10:973–86.

    Article  CAS  PubMed  Google Scholar 

  4. Zhang L, Zeng L, Gao X, Wang H, Zhu Y. Transformation of organ donation in China. Transpl Int. 2015;28:410–5.

    Article  PubMed  Google Scholar 

  5. Xia W, Ke Q, Wang Y, et al. Donation after cardiac death liver transplantation: graft quality evaluation based on pretransplant liver biopsy. Liver Transpl. 2015;21:838–46.

    Article  PubMed  Google Scholar 

  6. Mateo R, Cho Y, Singh G, et al. Risk factors for graft survival after liver transplantation from donation after cardiac death donors: an analysis of OPTN/UNOS data. Am J Transplant. 2006;6:791–6.

    Article  CAS  PubMed  Google Scholar 

  7. Chan EY, Olson LC, Kisthard JA, et al. Ischemic cholangiopathy following liver transplantation from donation after cardiac death donors. Liver Transpl. 2008;14:604–10.

    Article  PubMed  Google Scholar 

  8. Foley DP, Fernandez LA, Leverson G, et al. Biliary complications after liver transplantation from donation after cardiac death donors: an analysis of risk factors and long-term outcomes from a single center. Ann Surg. 2011;253:817–25.

    Article  PubMed  PubMed Central  Google Scholar 

  9. Cameron AM, Busuttil RW. Ischemic cholangiopathy after liver transplantation. Hepatobiliary Pancreat Dis Int. 2005;4:495–501.

    PubMed  Google Scholar 

  10. Eltzschig HK, Eckle T. Ischemia and reperfusion-from mechanism to translation. Nat Med. 2011;17:1391–401.

    Article  CAS  PubMed  Google Scholar 

  11. Wang C, Chen K, Xia Y, et al. N-acetylcysteine attenuates ischemia-reperfusion-induced apoptosis and autophagy in mouse liver via regulation of the ROS/JNK/Bcl-2 pathway. PLoS One. 2014;9:e108855.

    Article  PubMed  PubMed Central  Google Scholar 

  12. Thampanitchawong P, Piratvisuth T. Liver biopsy: complications and risk factors. World J Gastroenterol. 1999;5:301–4.

    Article  PubMed  PubMed Central  Google Scholar 

  13. Vuppalanchi R, Unalp A, Van Natta ML, et al. Effects of liver biopsy sample length and number of readings on sampling variability in nonalcoholic fatty liver disease. Clin Gastroenterol Hepatol. 2009;7:481–6.

    Article  PubMed  Google Scholar 

  14. Zhang YQ, Shan H, Kong QC, et al. Using 1H-MRS to evaluate the effects of warm ischemia reperfusion injury on the regeneration of hepatic cells in orthotopic transplanted livers in rats. Zhonghua Gan Zang Bing Za Zhi. 2008;16:274–8.

    CAS  PubMed  Google Scholar 

  15. Chow AM, Chan KW, Fan SJ, et al. In vivo proton magnetic resonance spectroscopy of hepatic ischemia/reperfusion injury in an experimental model. Acad Radiol. 2011;18:246–52.

    Article  PubMed  Google Scholar 

  16. Wu X, Wang H, Chen F, et al. Rat model of reperfused partial liver infarction: characterization with multiparametric magnetic resonance imaging, microangiography, and histomorphology. Acta Radiol. 2009;50:276–87.

    Article  CAS  PubMed  Google Scholar 

  17. Guo CW, Shen SD, Zhang Y, Liang CH, Yi XL, Luo W. Determination of apparent diffusion coefficient to quantitatively study partial hepatic ischemia reperfusion injury in a rabbit model. Transplant Proc. 2011;43:1474–9.

    Article  CAS  PubMed  Google Scholar 

  18. Cheung JS, Fan SJ, Chow AM, Hui ES, Wu EX. In vivo DTI assessment of hepatic ischemia reperfusion injury in an experimental rat model. J Magn Reson Imaging. 2009;30:890–5. Erratum in: J Magn Reson Imaging 2010;31:515

    Article  PubMed  Google Scholar 

  19. Le Bihan D, Breton E, Lallemand D, Grenier P, Cabanis E, Laval-Jeantet M. MR imaging of intravoxel incoherent motions: application to diffusion and perfusion in neurologic disorders. Radiology. 1986;161:401–7.

    Article  CAS  PubMed  Google Scholar 

  20. Le Bihan D. Intravoxel incoherent motion perfusion MR imaging: a wake-up call. Radiology. 2008;249:748–52.

    Article  PubMed  Google Scholar 

  21. Tosun M, Inan N, Sarisoy HT, et al. Diagnostic performance of conventional diffusion weighted imaging and diffusion tensor imaging for the liver fibrosis and inflammation. Eur J Radiol. 2013;82:203–7.

    Article  PubMed  Google Scholar 

  22. Chuck NC, Steidle G, Blume I, Fischer MA, Nanz D, Boss A. Diffusion tensor imaging of the kidneys: influence of b-value and number of encoding directions on image quality and diffusion tensor parameters. J Clin Imaging Sci. 2013;3:53.

    Article  PubMed  PubMed Central  Google Scholar 

  23. Jin N, Deng J, Chadashvili T, et al. Carbogen gas-challenge BOLD MR imaging in a rat model of diethylnitrosamine-induced liver fibrosis. Radiology. 2010;254:129–237.

    Article  PubMed  Google Scholar 

  24. Hu G, Chan Q, Quan X, et al. Intravoxel incoherent motion MRI evaluation for the staging of liver fibrosis in a rat model. J Magn Reson Imaging. 2015;42:331–9.

    Article  PubMed  Google Scholar 

  25. Luciani A, Vignaud A, Cavet M, et al. Liver cirrhosis: intravoxel incoherent motion MR imaging--pilot study. Radiology. 2008;249:891–9.

    Article  PubMed  Google Scholar 

  26. Li X, Liang Q, Zhuang L, et al. Preliminary study of MR diffusion tensor imaging of the liver for the diagnosis of hepatocellular carcinoma. PLoS One. 2015;10:e0135568.

    Article  PubMed  PubMed Central  Google Scholar 

  27. Zhu L, Cheng Q, Luo W, Bao L, Guo G. A comparative study of apparent diffusion coefficient and intravoxel incoherent motion-derived parameters for thecharacterization of common solid hepatic tumors. Acta Radiol. 2015;56:1411–8.

    Article  PubMed  Google Scholar 

  28. Bane O, Besa C, Wagner M, et al. Feasibility and reproducibility of BOLD and TOLD measurements in the liver with oxygen and carbogen gaschallenge in healthy volunteers and patients with hepatocellular carcinoma. J Magn Reson Imaging. 2016;43:866–76.

    Article  PubMed  Google Scholar 

  29. Ye W, Li J, Guo C, et al. Can intravoxel incoherent motion diffusion-weighted imaging characterize the cellular injury and microcirculation alteration in hepatic ischemia-reperfusion injury? An animal study. J Magn Reson Imaging. 2016;43:1327–36.

    Article  PubMed  Google Scholar 

  30. Le Bihan D, Turner R, MacFall JR. Effects of intravoxel incoherent motions (IVIM) in steady-state free precession (SSFP) imaging: application to molecular diffusion imaging. Magn Reson Med. 1989;10:324–37.

    Article  CAS  PubMed  Google Scholar 

  31. Park HJ, Kim YK, Min JH, Lee WJ, Choi D, Rhim H. Feasibility of blood oxygenation level-dependent MRI at 3T in the characterization of hepatic tumors. Abdom Imaging. 2014;39:142–52.

    Article  PubMed  Google Scholar 

  32. Bedossa P, Poynard T. An algorithm for the grading of activity in chronic hepatitis C. The METAVIR Cooperative Study Group. Hepatology. 1996;24:289–93.

    Article  CAS  PubMed  Google Scholar 

  33. Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics. 1977;33:159–74.

    Article  CAS  PubMed  Google Scholar 

  34. Nishida T, Ueshima S, Kazuo H, Ito T, Seiyama A, Matsuda H. Vagus nerve is involved in lack of blood reflow into sinusoids after rat hepatic ischemia. Am J Physiol Heart Circ Physiol. 2000;278:H1565–70.

    CAS  PubMed  Google Scholar 

  35. Davis TL, Kwong KK, Weisskoff RM, Rosen BR. Calibrated functional MRI: mapping the dynamics of oxidative metabolism. Proc Natl Acd Sci USA. 1998;95:1834–9.

    Article  CAS  Google Scholar 

  36. Jajamovich GH, Dyvorne H, Donnerhack C, Taouli B. Quantitative liver MRI combining phase contrast imaging, elastography, and DWI: assessment of reproducibility and postprandial effect at 3.0 T. PLoS One. 2014;9:e97355.

    Article  PubMed  PubMed Central  Google Scholar 

  37. Haque M, Koktzoglou I, Li W, Carbray J, Prasad P. Functional MRI of liver using BOLD MRI: effect of glucose. J Magn Reson Imaging. 2010;32:988–91.

    Article  PubMed  Google Scholar 

  38. Choi JW, Kim H, Kim HC, et al. Blood oxygen level-dependent MRI for evaluation of early response of liver tumors to chemoembolization: ananimal study. Anticancer Res. 2013;33:1887–92.

    CAS  PubMed  Google Scholar 

Download references

Acknowledgements

We would like to acknowledge Pan Li Zuo for her help with designing MR sequences, and Wen Juan Cai for her help with performing the histological examination of the liver in this study.

Funding

This work was supported by grants from National Natural Science Foundation of China (grant No. 81301197).

Availability of data and materials

The datasets used and/or analysed during the current study are available from the corresponding author on reasonable request.

Author information

Authors and Affiliations

Authors

Contributions

JQ, SW and LGM designed the study. JQ and ZLJ analyzed the data, and were major contributors in writing the manuscript. CZQ,XSC and RT performed the rabbit surgery and MR scan. All authors read and approved the final manuscript.

Corresponding authors

Correspondence to Wen Shen or Guang Ming Lu.

Ethics declarations

Ethics approval

The protocols and procedures were approved by the local Animal Experimentation Ethics Committee (No: 2017N030KY).

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Ji, Q., Chu, Z.Q., Ren, T. et al. Multiparametric functional magnetic resonance imaging for evaluation of hepatic warm ischemia-reperfusion injury in a rabbit model. BMC Gastroenterol 17, 161 (2017). https://doi.org/10.1186/s12876-017-0720-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12876-017-0720-8

Keywords