Skip to main content

Table 2 Diagnostic performance of graded hepatic steatosis

From: Comparative study of ultrasound attenuation analysis and controlled attenuation parameter in the diagnosis and grading of liver steatosis in non-alcoholic fatty liver disease patients

 

AUC(95%CI)

Cut-off(95%CI)

Specificity (%)

Sensitivity (%)

Accuracy (%)

P

level 0

0.96(0.93–0.99)

0.54(0.53–0.57)

95.50

93.60

95.00

< 0.0001

level 1

0.86(0.78–0.93)

0.59(0.58–0.63)

87.00

81.30

83.30

< 0.0001

level 2

0.81(0.71–0.91)

0.73(0.68–0.74)

65.70

89.10

79.01

0.0311

level 3

0.87(0.79–0.95)

0.86(0.82–0.88)

76.50

88.60

81.40

0.0092

  1. AUC, Area Under the Curve; CI, confidence interval; level 0 represents normal subjects vs. all hepatic steatosis patients. level 1 represents normal individuals vs. mild hepatic steatosis patients. level 2 represents patients with mild hepatic steatosis vs. patients with moderate hepatic steatosis. level 3 represents patients with moderate hepatic steatosis vs. patients with severe hepatic steatosis