Table 1 Study characteristics of pancreatic extracorporeal shock wave lithotripsy

From: Adverse events of pancreatic extracorporeal shock wave lithotripsy: a literature review

Author, Year

Country

Sample size1

Lithotripters2

Intensity

Frequency (shock waves/min)

Number of shock waves per session

Treatment time per session (min)

anaesthesia means3

Sauerbruch et al. 1987 [2]

Germany

1

Dornier HM3

18 KV

N/A

1200

40

GA

Sauerbruch et al. 1989 [52]

Germany

8

Dornier HM3

18 kV

N/A

1356

36

GA or IA

Kerzel et al. 1989 [53]

Germany

1

Wolf Piezolith 2300

Levels III-IV 4

 N/A

5600

45

WOA

Delhaye et al. 1992 [3]

Belgium

123

Siemens Lithostar

10-19KV

100

2862

60

IA

Sauerbruch et al. 1992 [54]

Germany

24

Dornier HM3

18-24 kV

N/A

1780

30–60

GA or IA

Van Der Hul et al. 1994 [55]

Netherland

17

Siemens Lithostar

16.2-19KV

N/A

3000–6000

 N/A

IA

Martin et al. 1995 [56]

USA

6

Dornier HM4

18–24 KV

N/A

1200–2400

 N/A

IA

Wolf et al. 1995 [57]

USA

14

Dornier HM3

20 KV

N/A

2000

N/A

IA

Schreiber et al. 1996 [58]

Austria

10

Dornier MPL 9000

19 KV

N/A

750

44

IA

Johanns et al. 1996 [4]

Germany

35

Dornier MPL 9000

14-22KV

N/A

2000

N/A

IA

Adamek et al. 1999 [59]

Germany

80

Wolf Piezolith 2300

Levels III-IV 4

 N/A

3500

60

IA

Karasawa et al. 2002 [60]

Japan

24

Wolf Piezolith 2500

Levels III-IV4

N/A

4200

N/A

WOA

Kozarek et al. 2002 [5]

USA

40

Dornier HM3

18–24 KV

N/A

1800–2400

 N/A

GA or EA

Lawrence et al.2010 [61]

USA

29

Storz Modulith SLX

7–8 KV

N/A

3000–6000

 N/A

GA

Tandan et al. 2010 [6]

India

1006

Dornier Delta Compact

15-16KV

90

5000

60–90

EA

Milovic et al. 2011 [62]

Germany

32

Storz Minilith SL 1

adjusted to the individual5

N/A

6800

N/A

WOA

Merrill et al. 2011 [63]

USA

30

Dornier HM3

Storz Modulith SLX-F2

Levels 3–94

Levels 3–94

90–120

90–120

3000–5000

3000–5000

 N/A

N/A

GA

GA

Li et al. 2014 [17]

China

634

Dornier Compact Delta II

10-16KV

60–120

5000

60–90

IA

Hu et al. 2016 [15]

China

214

Dornier Compact Delta II

16KV

100

5000

60–90

IA

Vaysse et al. 2016 [64]

France

146

Dornier Delta Compact

adjusted to the individual5

100

1200–6000

 N/A

IA

Tandan et al. 2019 [18]

India

5124

Dornier Delta Compact

15-16KV

90

5000–6000

 N/A

EA

Korpela et al. 2016 [65]

Finland

83

Storz Modulith SLX

Storz Modulith SLX-F2

Levels 64

Levels 44

60–90

60–90

3000

3000

 N/A

N/A

N/A

N/A

Lapp et al. 2016 [66]

USA

37

Wolf Piezolith 3000

18KV

N/A

2500

N/A

N/A

Hao et al. 2019 [47]

China

1404

Dornier Compact Delta II

16KV

120

5000

60–90

IA

Liu et al. 2019 [67]

China

106

Dornier Compact Delta II

16KV

100

5000

60–90

IA

Hyun et al. 2021 [68]

USA

97

Storz Modulith SLX-F2

Levels 6–74

 N/A

3000–5500

 N/A

GA

  1. 1Some studies have sample size overlaps: The sample size of Reference 47 is included in Reference 48; The sample size of Reference 6 is included in Reference 14; The sample size of Reference 11 is included in Reference 13, and they are all included in Reference 41
  2. 2The type of lithotripter is represented by company name and machine model
  3. 3 GA: general anaesthesia; IA: intravenous anaesthesia; EA: epidural anaesthesia; WOA: without anaesthesia
  4. 4Only energy level settings are available in studies, and specific energy parameters are unknown
  5. 5 “adjusted to the individual” means energy level or number of shock waves are tailored to the individual pain tolerance of the patient