Skip to main content

Table 4 Physiological measurements in CRAI and non-CRAI groups in the left-lateral and erect positions

From: Effect of posture on anorectal manometric measurements in female patients with fecal incontinence and rectoanal intussusception

 

Left-lateral position

Erect position

P value*

CRAI (n = 30)

   

 Anal canal length, cm

4.6 (3.2‒6.6)

4.3 (2.2‒6.0)

0.031

 Maximum resting pressure, cm H2O

51.5 (34.9‒124.8)

58.9 (18.7‒151.1)

0.023

 Maximum squeeze pressure, cm H2O

145.3 (65.1‒604.0)

118.7 (59.0‒454.4)

0.006

 Defecation desire volume, ml

85 (50‒250)

138 (40‒300)

< 0.0001

 Maximum tolerated volume, ml

170 (80‒300)

218 (60‒300)

< 0.0001

Non-CRAI (n = 50)

   

 Anal canal length, cm

4.5 (2.5‒6.5)

4.0 (1.8‒6.8)

0.005

 Maximum resting pressure, cm H2O

58.5 (19.0‒114.4)

65.2 (28.9‒156.0)

0.001

 Maximum squeeze pressure, cm H2O

150.5 (45.7‒366.7)

164.5 (44.0‒388.7)

0.788

 Defecation desire volume, ml

80 (20‒280)

120 (30‒280)

< 0.0001

 Maximum tolerated volume, ml

200 (70‒300)

215 (30‒300)

0.007

  1. Values are presented as median (range)
  2. CRAI circumferential rectoanal intussusception
  3. *Wilcoxon signed rank test