Skip to main content

Table 6 Results of biliary tract trimming between two groups

From: The application of magnetic anchoring traction device in assisting donor liver bench surgery in classic orthotopic liver transplantation

Variants

MAT group (n = 10)

Manual group (n = 10)

P value

Test methods

Number of assistants

0

0

 > 0.999

MWW

Number of magnetic anchoring traction devices used

0

0

  

Exposure quality (good/medium/bad)

10/0/0

10/0/0

 > 0.999

MWW

Vascular wall damage (yes/no)

0/10

0/10

  

Events of vascular wall damage occurred

0

0

 > 0.999

MWW

Procedure time (min)

6 (5, 10)

10 (7, 10)

0.218

MWW

  1. *indicates P < 0.05