From: Convolutional neural network-based system for endocytoscopic diagnosis of early gastric cancer
 | CNN | Endoscopist B | P value |
---|---|---|---|
Accuracy, % (95% CI) | 86.1 (75.9–93.1) | 70.8 (58.9–81.0) | 0.042 |
Sensitivity, % (95% CI) | 82.1 (66.5–92.5) | 53.8 (37.2–69.9) | 0.014 |
Specificity, % (95% CI) | 90.9 (75.7–98.1) | 90.9 (75.7–98.1) | 1 |
PPV, % (95% CI) | 91.4 (76.9–98.2) | 87.5 (67.6–97.3) | 0.68 |
NPV, % (95% CI) | 81.1 (64.8–92.0) | 62.5 (47.4–76.0) | 0.092 |