Skip to main content

Table 7 Results of overall surgery between MAT group and manual group

From: The application of magnetic anchoring traction device in assisting donor liver bench surgery in classic orthotopic liver transplantation

Variants

MAT group (n = 10)

Manual group (n = 10)

P value

Test methods

Number of assistants

1.0 (1.0, 1.0)

1.5 (1.0, 2.0)

0.035*

MWW

Number of magnetic anchoring traction devices used

4 (2, 4)

0

  

Exposure quality (Good/Medium/Bad)

9/1/0

4/3/3

0.043*

MWW

Vascular wall damage (Yes/No)

1/9

3/7

0.582

Fisher’s

Events of vascular wall damage occurred

0 (0, 0)

0 (0, 1)

0.481

MWW

Procedure time (min)

55 (51, 71)

85 (54, 85)

0.247

MWW

  1. *P < 0.05