Table 4 Linear mixed-effects model analysis between hemostatic device and postoperative day for each parameter

From: Comparison of operative outcomes between monopolar and bipolar coagulation in hepatectomy: a propensity score-matched analysis in a single center

 

Monopolar

Bipolar

P valuea

P valueb

P valuec

Parameter

Average

SE

95% CI

Average

SE

95% CI

Aspartate transaminase

298

21

257, 339

167

20.8

125, 208

 < 0.001

 < 0.001

 < 0.001

C-reactive protein

5.8

0.30

5.1, 6.4

6.0

0.3

5.3, 6.6

0.602

 < 0.001

 < 0.001

Albumin

2.9

0.04

2.8, 3.0

3.0

0.04

3.0, 3.1

0.020

0.135

0.026

  1. P values were calculated using the linear mixed-effects model for repeated measures. Significant P values are in boldface
  2. SE, standard error; CI, confidence interval
  3. aP value between hemostatic devices
  4. bP value between postoperative days
  5. cP value between hemostatic device and postoperative day