Fig. 1 | BMC Gastroenterology

Fig. 1

From: Duodenal perforations secondary to a migrated biliary plastic stent successfully treated by endoscope: case-report and review of the literature

Fig. 1

Duodenal perforation due to biliary plastic migration successfully managed by endoscope. a and b Coronal CT scan of the abdomen demonstrated that the biliary plastic stent (red arrow) had migrated and perforated through the duodenal wall. c Distal tip of biliary stent (black arrow) penetrated the duodenal wall which was confirmed during endoscope. d The migrated plastic stent was extracted by snare and perforation was detected during endoscopy. e The defect was successfully closed by hemostatic clips (blue arrow). f An endoscopic nasobiliary drainage (ENBD) tube (yellow arrow) was then inserted