Table 3 Comparison of complications of 347 PPC intervention patients according to different intervention methods

From: Identification of risk factors for pancreatic pseudocysts formation, intervention and recurrence: a 15-year retrospective analysis in a tertiary hospital in China

Total (n = 347)

Endoscopic

Surgical

Percutaneous drainage

P-value

48

164

135

 

Infection

5

13

22

0.076

Hemorrhage

2

5

5

0.914

Anastomotic/Percutaneous Leakage

3

4

7

0.342

Pancreatitis exacerbation

2

2

1

0.219

Organ failure

1

2

2

0.906

Mortality

1

1

3

0.464

Recurrence

4

8

22

0.004a

  1. aStatistically significant results (P < 0.050)