Skip to main content

Table 3 Published series of PEGs by the Introducer Technique

From: Assessment of safety and feasibility of a new technical variant of gastropexy for percutaneous endoscopic gastrostomy: an experience with 435 cases

Author [ref]

Year

Gastropexy

Antibiotics

N

Infection

(N)

Infection

(%)

Russell TR [12]

1984

No

N/A

28

1

3.6

Hashiba K [19]

1987

Suture

N/A

56

0

0.0

Kadota T [13]

1991

No

N/A

89

3

3.4

Robertson FM [18]

1996

Fogarty

Yes

20

0

0.0

Tucker AT [16]

2003

T-fastener

Yes

29

0

0.0

Maetani I [4]

2003

No

Yes

29

0

0.0

Dormann AJ [9]

2006

Suture

Yes

46

1

2.2

Saito M [11]

2007

Suture

N/A

82

0

0.0

Campoli PMO [8]

2007

Suture

No

142

4

2.8

Toyama Y [20]

2007

Suture

Yes

30

1

3.3

Foster JM [17]

2007

T-fastener

No

149

5

3.4

Shastri YM [14]

2008

Suture

Yes

47

1

2.1

Shastri YM [14]

2008

Suture

No

46

1

2.2

Horiuchi A [5]

2008

Suture

Yes

68

0

0.0

Current series

2008

Suture

No

435

1

0.2

Pooled

   

1,296

18

1.4

[95%CI: 0.9–2.2]

  1. N/A, information not available
  2. CI, Confidence Interval