Skip to main content

Table 4 Case series evaluating the outcomes of self-expandable plastic stents for benign esophageal diseases

From: A comparison of the temporary placement of 3 different self-expanding stents for the treatment of refractory benign esophageal strictures: a prospective multicentre study

Author (reference)

Patients (n)

Esophageal strictures (n)

Clinical success n (%)

Complications

Evrard et al. [11]

21

17

13/17 (76.5%)

Migration 9/17 (52.9%)

Repici et al. [10]

15

15

12/15 (80%)

Migration 1/15 (6.7%)

Martin et al. [15]

42

18

17/18 (94.4%)

Migration 1/18 (5.5%)

Holm et al. [2]

30

22

5/83 interventions (6%)

Migration 53/83 stents placed (63.9%)

Dua et al. [6]

40

40

12/40 (25%)

Migration 8/40 (22%) Perforation 2/40 (5%) Bleeding 3/40 (7.5%) Mortality 1/40 (2.5%)

Oh et al. [12]

13

13

3/13 (23%)

Migration 4/13 (30.8%)

Triester et al. [13]

5

5

0/5 (0%)

Migration 3/5 (60%) Perforation 1/5 (20%) Severe chest pain 1/5 (20%)

Barthel et al. [14]

8

8

1/8 (12.5%)

Migration 11/13 (85%)